Skip to main content

BME688 Environmental Sensor - Troubleshooting

This page contains some tips in case you are having problems using this product.

Check wiring

Ensure that your Qwiic cable is properly connected and in good condition. Try using the same cable with another Qwiic-compatible device to verify that it works. If the issue persists, swap it out for a different cable to rule out any possible damage or defects.

Check I2C pins

If you are connecting the sensor using standard I2C pins on your microcontroller, double-check that you are using the correct ones. Different microcontrollers have designated I2C pins that may not always be labeled the same way. Refer to your microcontroller's documentation to confirm the correct pin assignments. Test

Scan for I2C devices

Run an I2C scanner sketch on your microcontroller to check if the sensor is detected. If the scanner does not find any devices, there might be a wiring issue, incorrect pull-up resistors, or a problem with the microcontroller’s I2C bus.

Check for conflicting devices

If you have multiple I2C devices connected to the same bus, ensure that none of them have conflicting addresses. The BME680 uses the fixed I2C address 0x76, so verify that no other device is using this address.

Try reinitializing

If the sensor fails to initialize on the first attempt, try calling bme688.begin() again in your code or resetting your microcontroller. Some initialization issues may be resolved by a simple reboot.

Add an offset

Because the sensor by itself generates heat, a temperature offset may be needed. You must find an independent temperature reading and apply the offset to the temperature value if needed

Take "Dummy" sensor readings

Because of the way the gas sensor works, taking infrequent readings may make them inaccurate. To combat this, take readings more frequently, even if you don't plan on using the values

ℹ️
In case you haven't found the answer to your question, please contact us via this link.